Product Details:
Minimum Order Quantity | 1 Piece |
Product Type | Static |
Usage/Application | Hospital |
Size | 2x2x2 |
Material | Stainless Steel |
Shape | Square |
Brand | Sterile |
PRODUCT INTRODUCTION
Sterile Tech TM Static Pass Boxes designed to minimize traffic and contamination entry into the clean room, enables parts, tools and other work items to be passed to room and from the room. Unit acts as an air lock device preventing ambient air from entering, or clean air from exiting the clean room.
U V lamp 1 No
Illumination LED Tube light –1 No
Power Supply 230-volt, single phase, 50 cycle
Doors Doors Swing type door with clear PC/Toughened Glass view panel, Electromagnetic interlock & door open/close indicator with beep
Worktable By IS 304 Grade Stainless Steel surface
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Product Type | dynamic pass box |
Usage/Application | Hospital |
Size | 2x2x2 |
Material | Stainless Steel |
Shape | Rectangular |
Brand | Sterile |
PRODUCT INTRODUCTION
Sterile Tech TM Dynamic Pass Boxes designed to minimize traffic and contamination entry into the clean room, enables parts, tools and other work items to be passed to and from the room. Unit acts as an air lock device preventing ambient air from entering, or clean air from exiting the clean room. Dynamic Pass Box allows operation in sterile and particle free conditions because the continuous flushing of the working area by a unidirectional and vertical and ultra-filtered airflow, it assures a full product protection.
Cleanliness Class 100 as per ISO 14644 –1
Direction of flow Vertical
Air Balancing 100% Re-circulation
Particle Retention 0.3 Micron & above
Down Flow Velocity 90 FPM ± 20
Noise level 60 decibel on “A” scale ± 5
Working Platform By IS 304 Grade Stainless Steel Table
Illumination LED light – 1 No
U V lamp 1 No
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Sterile |
Type | Vertical |
Material | GI Powder coated |
Surface Finish | Powder Coated |
Usage/Application | Laboratory |
Color | White powder coated |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Product Type | Static |
Usage/Application | Hospital |
Size | 2x2x2 |
Material | powder coated |
Shape | Square |
Brand | Sterile |
PRODUCT INTRODUCTION
Sterile Tech TM Static Pass Boxes designed to minimize traffic and contamination entry into the clean room, enables parts, tools and other work items to be passed to room and from the room. Unit acts as an air lock device preventing ambient air from entering, or clean air from exiting the clean room.
U V lamp 1 No
Illumination LED Tube light –1 No
Power Supply 230-volt, single phase, 50 cycle
Doors Doors Swing type door with clear PC/Toughened Glass view panel, Electromagnetic interlock & door open/close indicator with beep
Worktable By IS 304 Grade Stainless Steel surface
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Brand | Sterile |
Type | Vertical |
Material | GI Powder coated |
Surface Finish | Powder Coated |
Usage/Application | Laboratory |
Color | White powder coated |
Additional Information:
Product Details:
Minimum Order Quantity | 1 no |
Brand | Sterile |
Type | Horizontal |
Material | GI Powder coated |
Surface Finish | Powder Coated |
Usage/Application | Laboratory |
Color | White powder coated |
Voltage | 230V |
Power Supply | 230V, Single phase, 50 Hz |
Noise Level | 65 decibel on "A" scale +- 5 |
Sterile Tech TM Ceiling Mounted Laminar Airflow
Ceiling Laminar Airflow are used for various applications such as, over a packing and filling lines in the pharmaceutical industry, food processing industry, in the assembly line of precious engineering components, pre-operative and post-operative care of critically ill patients and widely being used inside the OPERATION THEATRE during critical surgery etc. CEILING SUSPENDED LAMINAR AIRFLOW provides ultra-clean sterile CLASS 100 clean air in an isolated area where various kinds of critical and highly sensitive process activities are carried out. CLAF is designed as per CLASS 5 OF ISO 14644-1 standards.
Additional Information:
Product Details:
Brand | Sterile |
Type | Vertical |
Material | GI Powder coated |
Surface Finish | Powder Coated |
Usage/Application | Laboratory |
Color | White powder coated |
Voltage | 230V |
Power Supply | 230V, Single phase, 50 Hz |
Noise Level | 65 decibel on "A" scale +- 5 |
PRODUCT INTRODUCTION
Sterile Tech TM Vertical Laminar Airflow
Vertical Laminar Airflow system allows operation in sterile and particle free conditions because the continuous flushing of the working area by a unidirectional and vertical and ultra filtered airflow, it assures a full product protection.
Cleanliness Class 100 as per ISO 14644-1
Direction of Flow Vertical
Particle Retention 0.3 Micron & Above
Noise Level 65 decibel on “A” scale ± 5
Velocity 90 Feet / Minute ± 20
Worktable By IS 304 Grade Stainless Steel surface
Door Framed Polycarbonate-Sliding type
U V lamp 1 No.
Illumination LED tube light-1No.
Pressure (∆P) Digital Magnehelic gauge-Low and High Pressure Indicator
Other accessories 5/15 Amp power point- 1No, Castor Wheel -1set, Gas Nozzle-1no
Power Supply 230V, Single phase, 50 Hz
Product Details:
Brand | Sterile |
Type | Horizontal |
Material | Stainless Steel |
Surface Finish | Polished |
Usage/Application | Laboratory |
Color | Stainless steel color |
Voltage | 230V |
Power Supply | 230V, Single phase, 50 Hz |
Noise Level | 65 decibel on "A" scale +- 5 |
Sterile Tech TM Horizontal Laminar Airflow
Horizontal Laminar Airflow system allows operation in sterile and particle free conditions because the continuous flushing of the working area by a unidirectional and Horizontal and ultra-filtered airflow, it assures a full product protection.
Cleanliness Class 100 as per ISO 14644-1
Direction of Flow Horizontal
Particle Retention 0.3 Micron & Above
Noise Level 65 decibel on “A” scale ± 5
Velocity 90 Feet / Minute ± 20
Worktable By IS 304 Grade Stainless Steel surface
Door Foldable Polycarbonate
Side View Toughened Glass /PC
U V lamp 1 No.
Illumination LED tube light-1No.
Pressure (∆P) Inclined Manometer
Other accessories 5/15 Amp power point- 1No, Castor Wheel -1set,Gas Nozzle-1no
Power Supply 230V, Single phase, 50 Hz
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Sterile |
Usage/Application | Industrial |
Material | stainless steel |
Corrosion Resistance | Yes |
PRODUCT INTRODUCTION
Sterile Tech TM Air Shower concentrated airflows to lift off contamination such as lint, dirt, dust etc., while an individual simply moves in or walks through a specially constructed chamber. The high velocity air from jet nozzles ensures efficient scrubbing action necessary to remove particulate matter. Contaminated air then flows through sidewalls of the air shower and flows through pre filters and final HEPA filters.
Additional Information:
Product Details:
Minimum Order Quantity | 1 no |
Brand | Sterile |
Usage/Application | Industrial |
Material | stainless steel |
Corrosion Resistance | Yes |
PRODUCT INTRODUCTION
Sterile Tech TM Air Shower concentrated airflows to lift off contamination such as lint, dirt, dust etc., while an individual simply moves in or walks through a specially constructed chamber. The high velocity air from jet nozzles ensures efficient scrubbing action necessary to remove particulate matter. Contaminated air then flows through sidewalls of the air shower and flows through pre filters and final HEPA filters.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Brand | Sterile |
PRODUCT INTRODUCTION
Sterile Tech TM Garment Storage Cabinet (Static)
The garments storage cabinets is consist of UV Lamp for Sterilization, IR Lamp to maintain the temperature, Swing type glass doors and horizontal partition are provided in the storage cabinet for keeping folded garments.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Country of Origin | Made in India |
Sterile Tech TM Fume Exhaust Hoods
Fume Cupboard is of constant supply air hood with auxiliary bye-pass provision. Three sides of the hood are permanently closed and the front side provided with sliding door..
Inside the working chamber, there will be a sturdy baffle provided at about 200mm above the work-table to uniformly direct the fumes / odour / smoke directly in to the hood’s exhaust system. Suction will be done at three different levels suitable for mild to heavy fumes
Additional Information:
Product Details:
Minimum Order Quantity | 1 Square Feet |
Brand | Sterile |
Usage/Application | Laboratory |
Material | Stainless Steel |
STERILE TECH TM Modular Clean Room CLASS 10,000 (ISO 7 of 14644-1) at rest
Scope: Design, supply, installation & testing of CLASS 10,000 Modular Clean Room facilities of Area-10 Lx 10W x 2.7H=100 sq.mtr approx.,
Design: The proposed MODULAR CLEANROOM with VERTICAL LAMINAR AIRFLOW will be designed with 90% air recirculation and 10% fresh air thus providing about 70 air change per hour. Fresh air taken through 10-micron pre-filters and 5micron filter at the AHU and the return air is collected through the return-air-raisers located on the wall panels. In-order to maintain a balanced pressure and to compensate continuous fresh air intake, At least 10% air is exhausted out.
Additional Information:
Product Details:
Minimum Order Quantity | 1 sq ft |
Material | Stainless |
Door Finishing | Polished |
STERILE TECH TM Modular Clean Room CLASS 1,00,000 (ISO 8 of 14644-1) at rest
Scope: Design, supply, installation & testing of CLASS 1,00,000 Modular Clean Room facilities of Area-10 Lx 10W x 2.7H=100 sq.mtr approx.,
Design: The proposed MODULAR CLEANROOM with VERTICAL LAMINAR AIRFLOW will be designed with 90% air recirculation and 10% fresh air thus providing about 35 air change per hour. Fresh air taken through 10-micron pre-filters and 5micron filter at the AHU and the return air is collected through the return-air-raisers located on the wall panels. In-order to maintain a balanced pressure and to compensate continuous fresh air intake, At least 10% air is exhausted out.
Additional Information:
Product Details:
Usage/Application | Clean Room |
Brand | Sterile Tech |
Color | Aluminium |
Feature | coving with back cover |
Finishing Type | Powder coated |
Length | 3meter |
Material | Aluminum |
Thickness | 50-200mm |
Application | Wall and Roof Panel |
Surface Treatment | Powder Coated |
Additional Information:
Product Details:
Feature | Soft Edges |
Color | White |
Material | PVC |
Brand | Sterile Tech |
Product Dimensions | R60 |
Usage/Application | Clean Room |
Surface Treatment | Powder Coated |
Additional Information:
Additional Information:
Additional Information:
Sandwich panels for Cleanroom systems are designed according to the latest GMP norms. Our array of quality is Modular Wall Panels, Walk-able & Non-walk able ceiling Panels with in fill material of PUF, EPS and Rockwool. Each and every component of the systems is engineered & developed for easy installation and functioning. Our Modular technology is very reasonable at cost and more flexible at usage. This whole system can be assembled and demounted with more ease.
Special Features of panels• Extremely Low Weight
• Excellent Strength
• High Resistance to Moisture
• High Resistance to Corrosion
• Excellent Thermal Conductivity
• Non Combustible
• High Resistance to Fungi
• Easy Installation
• Easily Cleanable
Additional Information:
Product Details:
Minimum Order Quantity | 150 Meter |
Application | Wall and Roof Panel |
Color | Aluminium |
Brand | Sterile Tech |
Usage/Application | Clean Room |
Feature | coving with back cover |
Finishing Type | Powder coated |
Length | 3meter |
Thickness | 50-200mm |
Surface Treatment | Powder Coated |
Material | Aluminum |
Additional Information:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Square Meter |
Brand | Sterile |
Color | White |
Material | PUF |
Country of Origin | Made in India |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Brand | sterile |
Country of Origin | Made in India |
Sterile TechTM Positive Pressure Module:
Pressure Module is designed to provide clean air in a small enclosure. These modules feeds filtered dust-free air to built-up and maintain positive pressure in the sterile area. The positive pressure effect caused by the module ensures that the air movement is always outside and prevents entry of contaminated air inside the sterile area.
Additional Information: