Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Sterile |
Type | Vertical |
Material | GI Powder coated |
Surface Finish | Powder Coated |
Usage/Application | Hospital |
Color | White powder coated |
Sterile Tech TM Ceiling Mounted Laminar Airflow
Ceiling Laminar Airflow are used for various applications such as, over a packing and filling lines in the pharmaceutical industry, food processing industry, in the assembly line of precious engineering components, pre-operative and post-operative care of critically ill patients and widely being used inside the OPERATION THEATRE during critical surgery etc. CEILING SUSPENDED LAMINAR AIRFLOW provides ultra-clean sterile CLASS 100 clean air in an isolated area where various kinds of critical and highly sensitive process activities are carried out. CLAF is designed as per CLASS 5 OF ISO 14644-1 standards.
Type through duct
Air flow Vertical, downward, ceiling mounted
Air velocity 90 feet per minute +/- 20%
HEPA FILTER face area 100% face area of the LAF is covered with HEPA filter
Particle retention 0.3 micron and above
Standards CLASS 5 of ISO of 14644-1/USFED STD209 E
Cleanliness CLASS 100
The cabinet will be hung from the ceiling using SS rope/Thread road. Access for servicing the HEPA filters will be provided from the bottom side of the unit, it can be easily removable.
HEPA FILTERS Separator less Mini-pleat HEPA in aluminium extruded frames with wire mesh protection and made of Ultra-fine Glass fiber media having a Retention capacity of 0.3 micron at 99.99% efficiency with initial pressure drop at 12 mm WG.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Brand | Sterile |
Type | Horizontal |
Material | Stainless Steel |
Surface Finish | Polished |
Usage/Application | Hospital |
Color | Stainless steel color |
Sterile Tech TM Ceiling Mounted Laminar Airflow
Ceiling Laminar Airflow are used for various applications such as, over a packing and filling lines in the pharmaceutical industry, food processing industry, in the assembly line of precious engineering components, pre-operative and post-operative care of critically ill patients and widely being used inside the OPERATION THEATRE during critical surgery etc. CEILING SUSPENDED LAMINAR AIRFLOW provides ultra-clean sterile CLASS 100 clean air in an isolated area where various kinds of critical and highly sensitive process activities are carried out. CLAF is designed as per CLASS 5 OF ISO 14644-1 standards.
Type through duct
Air flow Vertical, downward, ceiling mounted
Air velocity 90 feet per minute +/- 20%
HEPA FILTER face area 100% face area of the LAF is covered with HEPA filter
Particle retention 0.3 micron and above
Standards CLASS 5 of ISO of 14644-1/USFED STD209 E
Cleanliness CLASS 100
The cabinet will be hung from the ceiling using SS rope/Thread road. Access for servicing the HEPA filters will be provided from the bottom side of the unit, it can be easily removable.
HEPA FILTERS Separator less Mini-pleat HEPA in aluminium extruded frames with wire mesh protection and made of Ultra-fine Glass fiber media having a Retention capacity of 0.3 micron at 99.99% efficiency with initial pressure drop at 12 mm WG.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Sterile |
Type | Horizontal |
Material | GI Powder coated |
Surface Finish | Powder Coated |
Usage/Application | Laboratory |
Color | White powder coated |
Sterile Tech TM Ceiling Mounted Laminar Airflow
Ceiling Laminar Airflow are used for various applications such as, over a packing and filling lines in the pharmaceutical industry, food processing industry, in the assembly line of precious engineering components, pre-operative and post-operative care of critically ill patients and widely being used inside the OPERATION THEATRE during critical surgery etc. CEILING SUSPENDED LAMINAR AIRFLOW provides ultra-clean sterile CLASS 100 clean air in an isolated area where various kinds of critical and highly sensitive process activities are carried out. CLAF is designed as per CLASS 5 OF ISO 14644-1 standards.
Type through duct
Air flow Vertical, downward, ceiling mounted
Air velocity 90 feet per minute +/- 20%
HEPA FILTER face area 100% face area of the LAF is covered with HEPA filter
Particle retention 0.3 micron and above
Standards CLASS 5 of ISO of 14644-1/USFED STD209 E
Cleanliness CLASS 100
The cabinet will be hung from the ceiling using SS rope/Thread road. Access for servicing the HEPA filters will be provided from the bottom side of the unit, it can be easily removable.
HEPA FILTERS Separator less Mini-pleat HEPA in aluminium extruded frames with wire mesh protection and made of Ultra-fine Glass fiber media having a Retention capacity of 0.3 micron at 99.99% efficiency with initial pressure drop at 12 mm WG.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Sterile |
Type | Horizontal |
Material | GI Powder coated |
Surface Finish | Polished |
Usage/Application | Laboratory |
Color | White powder coated |
Voltage | 230V |
Power Supply | 230V, Single phase, 50 Hz |
Noise Level | 65 decibel on "A" scale +- 5 |
Sterile Tech TM Ceiling Mounted Laminar Airflow
Ceiling Laminar Airflow are used for various applications such as, over a packing and filling lines in the pharmaceutical industry, food processing industry, in the assembly line of precious engineering components, pre-operative and post-operative care of critically ill patients and widely being used inside the OPERATION THEATRE during critical surgery etc. CEILING SUSPENDED LAMINAR AIRFLOW provides ultra-clean sterile CLASS 100 clean air in an isolated area where various kinds of critical and highly sensitive process activities are carried out. CLAF is designed as per CLASS 5 OF ISO 14644-1 standards.
Type through duct
Air flow Vertical, downward, ceiling mounted
Air velocity 90 feet per minute +/- 20%
HEPA FILTER face area 100% face area of the LAF is covered with HEPA filter
Particle retention 0.3 micron and above
Standards CLASS 5 of ISO of 14644-1/USFED STD209 E
Cleanliness CLASS 100
The cabinet will be hung from the ceiling using SS rope/Thread road. Access for servicing the HEPA filters will be provided from the bottom side of the unit, it can be easily removable.
HEPA FILTERS Separator less Mini-pleat HEPA in aluminium extruded frames with wire mesh protection and made of Ultra-fine Glass fiber media having a Retention capacity of 0.3 micron at 99.99% efficiency with initial pressure drop at 12 mm WG.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Sterile |
Usage/Application | Hospital |
Material | Stainless Steel |
Size | 2x2x2 |
Height | 2 |
Color | Stainless Steel color |
PRODUCT INTRODUCTION
Sterile Tech TM Static Pass Boxes designed to minimize traffic and contamination entry into the clean room, enables parts, tools and other work items to be passed to room and from the room. Unit acts as an air lock device preventing ambient air from entering, or clean air from exiting the clean room.
U V lamp 1 No
Illumination LED Tube light –1 No
Power Supply 230-volt, single phase, 50 cycle
Doors Doors Swing type door with clear PC/Toughened Glass view panel, Electromagnetic interlock & door open/close indicator with beep
Worktable By IS 304 Grade Stainless Steel surface
Additional Information:
Product Details:
Minimum Order Quantity | 1 no |
Brand | Sterile |
Type | Vertical |
Material | Stainless Steel |
Surface Finish | Polished |
Color | Stainless steel color |
Sterile Tech TM Fume Exhaust Hoods
Fume Cupboard is of constant supply air hood with auxiliary bye-pass provision. Three sides of the hood are permanently closed and the front side provided with sliding door..
Inside the working chamber, there will be a sturdy baffle provided at about 200mm above the work-table to uniformly direct the fumes / odour / smoke directly in to the hood’s exhaust system. Suction will be done at three different levels suitable for mild to heavy fumes
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Hospital/Labs |
Material | Steel |
Sterile Tech TM Ceiling Mounted Laminar Airflow
Ceiling Laminar Airflow are used for various applications such as, over a packing and filling lines in the pharmaceutical industry, food processing industry, in the assembly line of precious engineering components, pre-operative and post-operative care of critically ill patients and widely being used inside the OPERATION THEATRE during critical surgery etc. CEILING SUSPENDED LAMINAR AIRFLOW provides ultra-clean sterile CLASS 100 clean air in an isolated area where various kinds of critical and highly sensitive process activities are carried out. CLAF is designed as per CLASS 5 OF ISO 14644-1 standards.
Type through duct
Air flow Vertical, downward, ceiling mounted
Air velocity 90 feet per minute +/- 20%
HEPA FILTER face area 100% face area of the LAF is covered with HEPA filter
Particle retention 0.3 micron and above
Standards CLASS 5 of ISO of 14644-1/USFED STD209 E
Cleanliness CLASS 100
The cabinet will be hung from the ceiling using SS rope/Thread road. Access for servicing the HEPA filters will be provided from the bottom side of the unit, it can be easily removable.
HEPA FILTERS Separator less Mini-pleat HEPA in aluminium extruded frames with wire mesh protection and made of Ultra-fine Glass fiber media having a Retention capacity of 0.3 micron at 99.99% efficiency with initial pressure drop at 12 mm WG.
Additional Information:
Product Details:
Minimum Order Quantity | 1 sq ft |
Country of Origin | Made in India |
Sterile Tech TM Ceiling Mounted Laminar Airflow
Ceiling Laminar Airflow are used for various applications such as, over a packing and filling lines in the pharmaceutical industry, food processing industry, in the assembly line of precious engineering components, pre-operative and post-operative care of critically ill patients and widely being used inside the OPERATION THEATRE during critical surgery etc. CEILING SUSPENDED LAMINAR AIRFLOW provides ultra-clean sterile CLASS 100 clean air in an isolated area where various kinds of critical and highly sensitive process activities are carried out. CLAF is designed as per CLASS 5 OF ISO 14644-1 standards.
Type through duct
Air flow Vertical, downward, ceiling mounted
Air velocity 90 feet per minute +/- 20%
HEPA FILTER face area 100% face area of the LAF is covered with HEPA filter
Particle retention 0.3 micron and above
Standards CLASS 5 of ISO of 14644-1/USFED STD209 E
Cleanliness CLASS 100
The cabinet will be hung from the ceiling using SS rope/Thread road. Access for servicing the HEPA filters will be provided from the bottom side of the unit, it can be easily removable.
HEPA FILTERS Separator less Mini-pleat HEPA in aluminium extruded frames with wire mesh protection and made of Ultra-fine Glass fiber media having a Retention capacity of 0.3 micron at 99.99% efficiency with initial pressure drop at 12 mm WG.
Additional Information:
Product Details:
Minimum Order Quantity | 1 sq ft |
Country of Origin | Made in India |
Ceiling Suspended Laminar Air Flow is used for Operation Theatre applications, Pharma filling & packing line etc. CLAF provides ultra clean sterile HEPA filtered CLASS 100 air in a remote area. The cabinet will be hang from the ceiling using rope or thread rod. Access for servicing the pre filters, blowers or AHU, HEPA filters will be provided from the bottom side of the unit. Side screens, made of clear flexible PVC curtain are provided for a height of about 300 mm from the HEPA filter level.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Hospital |
Color | Silver |
Door Open Style | Hinged |
Country of Origin | Made in India |
PRODUCT INTRODUCTION
Sterile Tech TM Metal Door
Standard Make List |
|
GI Sheet |
Tata |
SS 304 |
JSW |
Powder Coat |
Jordon-IFB white |
Additional Information: